Choose a flameproof LED wellglass or floodlight by the lighting task and a verified layout, then check the exact fitting against the hazardous-area requirements. Wattage alone cannot tell you whether an operator can read an instrument, see a walkway or work without uncomfortable glare.
A wellglass fitting is commonly considered for local downward illumination. A floodlight is commonly considered when an adjustable aiming direction and wider-area coverage are useful. The actual optical distribution and photometric calculation decide whether either option works in your installation.
Start with what people need to see
Mark the working planes on a layout: floors, platforms, valve positions, stair treads and instrument faces. Include mounting heights, obstructions and normal operator viewing directions. A high lumen figure at the luminaire does not establish useful illumination at a shaded gauge behind pipework.
Ask the lighting designer to define the maintained illumination, uniformity and glare criteria required by the project. These should reflect the actual tasks and applicable workplace requirements. Do not adopt one generic lux figure for every industrial area.
Compare the fitting styles
| Question |
|---|